Initial Release of the 1909 TS Collection on 2019.12.02. Several changes from the last time published. This also incorporates the updated Pre-Caching Process for Drivers & Language Packs. I still need to blog the Language Pack process, but time is a luxury I rarely have for blogging. More details about the overall process can be found HERE (the 1809 WaaS Process)
WaaS 1909 TS Collection v2019.12.02 (2589 downloads)
Some Changes... the ones I could remember... full change logs are in the download, and it's rather extensive, so here is a short manual version.
2019.09.09
- CompatScan TS Change
- Changed Behavior to Skip running the TS the machine was already on 1809. (Adding Group w/ Condition)
- Changed Steps that called powershell.exe to use full path.
- Added Steps to Cleanup Registry Keys that MIGHT have been created on Previous runs
- Added section for Logging on Failure
- Added SetupDiag on Failure (Embedded PS Script)
- Changed Reporting Script (Process CompatScan Results) into an embedded Script
- Changed "Copy Logs to Server" Script to be embedded and modifed Script.
- Upgrade TS Change
- Changed Steps that called powershell.exe to use full path.
- Added section for Logging on Failure
- Added SetupDiag Always Runs (Embedded PS Script)
- Changed "Copy Logs to Server" Script to be embedded and modifed Script.
2019.09.20
- Package Change
- Tools & Scripts Package
- RollbackRecovery.ps1
- Added SetupDiag Tool (Requires Setup Diag in c:\programdata\WaaS, which would be added during PreCache)
- Added Repair for CMClient if WMI issue
- Added additional Logging for the above mentioned items.
- RollbackRecovery.ps1
- Tools & Scripts Package
2019.12.02
- Lots of changes, so many I honestly don't recall them all.. but I'll name a few
- Changed to 1909 and confirmed it all worked. Yippy!
- Main Upgrade TS… added folder near start of TS which will only run if.. NOT Deployment_Success or 1909… prevent the TS re-running again on accident if deployed again.. it happens
- Worked on Replacing the Error handing that Adam Gross blogged about with a completely powershell modular replacement.
- Added Inventory 2.1 script which records additional items as well as runs SetupDiag and writes to WaaS\SetupDiag\BuildNumber Key
- More things… but I don't remember right now…





Ok, hope this helps and you find it useful. Please continue to provide feedback.
GARYTOWN